Blocked vs unblocked shear walls

I expect this has more to do with the buckling strength of the sheathing. 16" OC studs provide more out of plane bracing to the panel than 24" OC would.

به خواندن ادامه دهید

Document Library | Resources | PABCO Gypsum

GA-229-2018 Shear Values for Screw Application of Gypsum Board on Walls Tests conducted in accordance with ASTM E72 to determine the shear resistance of gypsum board applied to wood stud partitions. Download GA …

به خواندن ادامه دهید

FREE PUBLICATIONS

Gypsum Board Typical Mechanical and Physical Properties, PDF Download - GA-235-2023 Item Number: GA-235-2023-PDF; Click For Info; Shear Values for Screw Application of Gypsum Board On Walls, PDF Download - GA-229-2023 Item Number: GA-229-2023-PDF; Click For Info; Recommendations for the Prevention of Ceiling Cracking, PDF Download - GA-227-2023 ...

به خواندن ادامه دهید

Shear Values for Screw Application of Gypsum Board On …

Category. Shear Values for Screw Application of Gypsum Board On Walls, PDF Download - GA-229-2023. ISBN: GA-229-2023-PDF. PDF Download. Description. Tests conducted in …

به خواندن ادامه دهید

GYPSUMATION

GA-229, Shear Values for Screw Application of Gypsum Board on Walls, presents shear values achieved using a variety of gypsum board thickness, screw types, and screw patterns. The …

به خواندن ادامه دهید

ER-5762 LEGACY REPORT Reissued July 1, 2003

Section: 09260—Gypsum Board Assemblies SURE-BOARD SERIES 200 STRUCTURAL PANELS INTERMAT 2045 PLACENTIA AVENUE COSTA MESA, CALIFORNIA 92627 1.0 SUBJECT Sure-Board Series 200 Structural Panels. ... 4.2 Nominal shear values for shear walls are limited to the values noted in Table 1. To determine the

به خواندن ادامه دهید

CHAPTER 25 GYPSUM BOARD AND PLASTER

Shear resisting values shall not exceed those set forth in Table 2506. 2506.1.2 All studs, top and bottom plates and blocking shall be nailed in accordance with Table 2506. 2506.1.3 The shear values tabulated shall not be cumula­ tive with the shear value of other materials applied to the same wall. Cumulative allowable shear values for walls

به خواندن ادامه دهید

CHAPTER 25 GYPSUM BOARD AND PLASTER

Wood-framed shear walls sheathed with gypsum board, lath and plaster shall be designed and constructed in accordance with Section 2306.3 and are permitted to resist wind and seismic loads. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 of ASCE 7. ... SHEAR VALUE a, b (plf of ceiling) MIMIMUM FASTENER SIZE ...

به خواندن ادامه دهید

SPECIFICATIONS

6.1 Spacing of framing members for multi-layer gypsum panel product systems shall be as specified in Tables 2 and 3. 6.2 The base and face layers of gypsum panel products shall be …

به خواندن ادامه دهید

General Information

Gypsum Board Typical Mechanical and Physical Properties, PDF Download - GA-235-2023 ... GA-235-2023-PDF; Click For Info; Shear Values for Screw Application of Gypsum Board On Walls, PDF Download - GA-229-2023 Item Number: GA-229-2023-PDF; Click For Info; Recommendations for the Prevention of Ceiling Cracking, PDF Download - GA-227-2023 ...

به خواندن ادامه دهید

Wood

NDS Table 4-2B Nominal Shear Capacity Rev 0 wns 030210.xls. Short Description: Submitted By: johndoyle-admin. Last Modified. 03 Mar 2010 . Downloads: 132. Rating: 2 Details . NDS Table A.4-2A Nominal Shear Capacity Rev 0 wns 030210.xls. Short Description: Submitted By: johndoyle-admin. Last Modified. 03 Mar 2010 .

به خواندن ادامه دهید

Capacity of 2-ply gypsum board shear walls

Capacity of 2-ply gypsum board shear walls structuresguy (Structural) (OP) ... The table provides two-ply values for 5/8" gyp. board. It doesn't look like you can get away with 24" o.c. though. If you go this route you would need to double the value since you have this two-ply construction on each side. Pay special attention to the fastening ...

به خواندن ادامه دهید

Shear Wall Report Dec 2004

Allowable shear value for walls with Gypsum Board on one side for wind and seismic 2 IBC 2003. International Building Code. International Code Council. Country Club Hills, IL. 2003. 9 FIGURE 8 - LOAD-DEFORMATION RELATIONSHIPS – TEST 1 FIGURE 9 - LOAD-DEFORMATION RELATIONSHIPS – TEST 2-5000-4000-3000-2000-1000 0 1000 2000

به خواندن ادامه دهید

FREE PUBLICATIONS

Gypsum Board Typical Mechanical and Physical Properties, PDF Download - GA-235-2023 Item Number: GA-235-2023-PDF; Click For Info; Shear Values for Screw Application of Gypsum …

به خواندن ادامه دهید

Revisiting Spanning the Gap

No matter what you call it, gypsum board is found in almost every type of construction. Architects use it for sound and fire ratings, while structural engineers need to account for its weight in our load calculations. ... The information is given as single fastener shear values for engineered design, and also screw spacing tables for common ...

به خواندن ادامه دهید

What is the screw substitution for cooler nails in Gypsum shear …

4)The Gypsum Association literature, GA-229-08, notes shear values for screw application but only at the 8" spacing. These value are less than the values of a ½" panel thickness at a 4" spacing. 5)The ESR-1338 also has values for screws but again, the only screw values in 5/8" gyp is at a 8/12 spacing.

به خواندن ادامه دهید

Values based on the unit shear capacity of interest

values based on the unit shear capacity of interest Alternatively the four term from CONSVTY 470A at University of Missouri, Kansas City

به خواندن ادامه دهید

GA-253-2021 APPLICATION OF GYPSUM SHEATHING

or shear value specified by the designer or applicable building code. 2. General Provisions 2.1 Gypsum sheathing shall not be used on exterior ceilings, soffits, or sills unless otherwise recommended by the manufacturer. 2.2 All wood framing members to which gypsum sheathing will be fastened shall be straight and true. Stud spacing

به خواندن ادامه دهید

GA-229-2018 Shear Values for Screw Application of Gypsum …

GA-229-2018 Shear Values for Screw Application of Gypsum Board On Walls. Tests conducted in accordance with ASTM E72 determine average ultimate shear values of …

به خواندن ادامه دهید

GA‐229‐2018 SHEAR VALUES FOR SCREW APPLICATION …

GA‐229‐2018 SHEAR VALUES FOR SCREW APPLICATION OF GYPSUM BOARD ON WALLS. A series of tests was conducted in accordance with ASTM E72 to determine the shear resistance of gypsum board applied to one side of wood stud partitions 16 in. (406 mm) o.c. using Type S …

به خواندن ادامه دهید

12-07

GA-229, Shear Values for Screw Application of Gypsum Board on Walls, presents shear values achieved using a variety of gypsum board thickness, screw types, and screw patterns. The document also provides conclusions reached after extensive testing of the different attachment configurations. This document has

به خواندن ادامه دهید

ExtErior Gypsum shEathinG

Gypsum board must be protected during transit with a weather-tight cover in good condition. Plastic shipping bags are intended to provide protection during transit ... Where wind or seismic forces require shear walls to resist these lateral forces, most building codes provide allowable shear values for walls having Exterior Gypsum Sheathing ...

به خواندن ادامه دهید

Type I Shear Walls

The shear values listed in Table 2211.2(2) shall not be cumulative with the shear values of other materials applied to the same wall unless otherwise permitted herein. The nominal shear values shown are for gypsum board that is applied to both sides of the wall.

به خواندن ادامه دهید

Sure-Board® For Shear

› Sure-Board® For Shear. Sure-Board® Series 200S-P Sheathing for Pitched Roofs. View Product. Sure-Board® Series 200S-F Sheathing for Floors and Flat Roofs. View Product. Sure-Board® Series 200B for Blast and Ballistics. View Product. Sure-Board® Series 200W for Wood Framing. View Product.

به خواندن ادامه دهید

Gypsum Sheathing: Keys For An Acceptable Installation

code or test report requirements. Shear values for all gypsum board products are typically contained in building code documents and code evaluation reports. Shear values are also contained in GA-253 and in GA-229, "Shear Val-ues for Screw Application of Gypsum Board on Walls." Use of panels as a shear- or seismic-resisting element may

به خواندن ادامه دهید

Sure-Board for Shear (200)

"SURE-BOARD" SHEAR WALL PROBLEMS IN FRAMING AND CONSTRUCTION ® Sure-Board is a steel sheet and gypsum or cement board composite. ® Sure-Board has a smooth gypsum board facing. ® Sure-Board is applied only on the section of wall that requires strength. ALSO AVAILABLE ® Sure-Board Series 200W For Wood Frame Walls •

به خواندن ادامه دهید

GA 229 2018 SHEAR VALUES FOR SCREW APPLICATION …

Shear values for ⅝ in. (15.9 mm) gypsum board exceed those for ½ in. (12.7 mm) gypsum board, Shear values increase with closer spacing of perimeter fasteners, and When compared to other shear test results, shear values for screws are higher than for nails.

به خواندن ادامه دهید

SHEAR VALUES FOR SCREW APPLICATION OF GYPSUM …

1. Shear values are comparable for both Type S and W screws, 2. Shear values for parallel application exceed those for perpendicular application, 3. Shear values for ⅝ in. (15.9 mm) …

به خواندن ادامه دهید

2306.3

Wood-frame shear walls shall be designed and constructed in accordance with AWC SDPWS.Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall be permitted. The allowable shear values in Tables …

به خواندن ادامه دهید

CFS Framed Shear Walls

It adds additional shear strength values for steel-sheet shear walls and limits diagonal strap braced walls to a 2:1 aspect ratio unless the chord studs are designed for the end moments. The seismic response modification coefficient, R, is currently 6.5 for wood and steel sheet-sheathed assemblies, 2.0 for gypsum board sheathing and 4.0 for ...

به خواندن ادامه دهید